Replacement for SolidFlow 1 and 2.0

SolidFlow discontinued? Your measuring point keeps running.

ENVEA has discontinued SolidFlow 1 and 2.0. With DYNAmflow, you replace them with a bulk solids flow meter based on the same microwave principle. We support you throughout the switch, from assessing your measuring point to calibration.

  • Same measuring principle: microwave, in free fall and in pneumatic conveying lines
  • Same measuring point: your existing application qualification remains valid
  • Supported changeover: free application check, on-site commissioning or remote calibration
DYNAmflow sensor on a pneumatic conveying line in an industrial plant

The situation

What the discontinuation means for you

ENVEA discontinued SolidFlow 1 and SolidFlow 2.0 in September 2026, according to the manufacturer without a direct successor. New units could be ordered until 30 September 2026; until December 2026, deliveries are made from stock only. ENVEA states that technical support and spare parts will be available until 30 September 2030, spare parts subject to availability (official ENVEA notice, PDF).

What this means for you: if a unit fails or a new measuring point is added, a new SolidFlow is no longer available. The earlier you plan the switch, the less your production depends on remaining stock.

You operate SolidFlow units

Plan the replacement before a failure forces your hand. We assess your measuring point and tell you what the switch involves, measuring point by measuring point if needed.

You design plants with SolidFlow

Specify current and new projects with an available device. In most cases, you can keep the measuring point and installation situation unchanged.

Your changeover

We take care of the switch

Same measuring principle, same measuring point: switching to DYNAmflow comes down to installation and calibration.

  1. Application check

    You send us the data of your measuring point using our questionnaire. We check free of charge whether DYNAmflow is the right fit.

  2. Sizing & quotation

    We specify the sensor and weld-on socket for your line. We supply the matching weld-on socket.

  3. Installation

    The new weld-on socket is fitted at the same measuring point and the sensor is mounted flush. Connection to your control system is via 4–20 mA or RS485 (Modbus RTU).

  4. Calibration

    Calibration takes place during operation using the MF-Config software. On request, our service engineers carry out commissioning and calibration on site or remotely.

Technical comparison

SolidFlow 2.0 and DYNAmflow at a glance

The key specifications of both devices, taken from the manufacturers’ documentation. The details that matter for your application are clarified with you in the application check.

Sources: ENVEA SolidFlow 2.0 product information DE, 03/08/2020; mütec MF 3001 operating manual, 01/2026 (DYNAmflow is identical in design to the MF 3000). Information without guarantee, subject to technical changes.
FeatureENVEA SolidFlow 2.0DYNAmflow
Measuring principlemicrowavemicrowave
Conveying typefree fall, pneumaticfree fall, pneumatic
Process connectionweld-on socket with clamping deviceown weld-in socket with lock nut
Flow rateup to 20 t/ha few kg/h up to approx. 20 t/h
Process temperature−20 … +80 °C, optional up to +200 °C−20 … +90 °C, optional up to +150 °C or +450 °C
Explosion protection (ATEX)dust zone 20 or gas zone 1 (optional)dust zone 20/21 (II 1/2 D Ex ta/tb IIIC T135 °C Da/Db) or gas zone 2 (II 3 G)
Sensor ingress protectionIP65IP65
Sensor materialstainless steel 1.4571stainless steel 1.4307, alternatively 1.4571
Outputs4–20 mA, relay, pulse, RS485, USB0/4–20 mA or 0/2–10 V, relay and transistor output (limit values), RS485 (Modbus RTU), USB
Calibrationrequiredrequired, with intelligent calibration assistant (MF-Config)
Roping compensationyesno – solved by selecting a suitable measuring point

Good to know before you switch

  • The weld-on socket is always replaced during the changeover: the SolidFlow probe sits in a clamping device, the DYNAmflow sensor in its own weld-on socket. We supply the matching socket; it is fitted at the same position.
  • We handle roping flows by selecting a suitable measuring point, which we determine together with you in the application check.
  • Calibration takes place during operation. The intelligent calibration assistant in the MF-Config software automatically adapts the sensor settings to process and material.

Our customers

  • HeidelbergCement
  • LafargeHolcim
  • Cargill
  • Omya
  • Bayer
  • DSM
  • Südzucker
  • K+S
DYNAmflow microwave sensor in stainless steel

The device

DYNAmflow: flow measurement for powders, dusts and granules

The sensor is mounted flush in the metallic conveying line and measures without contact and without wear. Deposits on the pipe wall do not affect the measurement.

  • Pipelines up to DN 300, vertical or horizontal
  • Up to 24 product curves can be stored, up to 16 switchable via digital input
  • High-temperature version up to +450 °C
  • MF-Config software with intelligent calibration assistant and totaliser function

Service

Local contacts wherever your plant is

Our own service engineers and more than 35 distributors and partners worldwide support your measuring points, from the switch to day-to-day operation.

Hundreds of DYNA installations in cement, chemicals, food and plastics worldwide.

FAQ

Questions about the switch

How long will the SolidFlow be supported?

According to the ENVEA notice, technical support and spare parts will be available until 30 September 2030, spare parts subject to component availability. New units have not been available to order since 30 September 2026.

Do I need to requalify my measuring point?

Usually not. DYNAmflow works on the same microwave principle; measuring point, conveying type and interfering factors stay the same. You can keep your existing application qualification. The only new step is calibrating the device during operation.

Can I keep using my existing socket?

No. The SolidFlow probe sits in a clamping device, while DYNAmflow is mounted in its own weld-on socket. We supply the matching socket; it is fitted at the same position, so the measuring point stays.

Can I keep my existing calibration?

No, every device is calibrated to your bulk material. The MF-Config software supports you by automatically adapting the sensor settings to process and material. On request, our service engineers calibrate on site or remotely.

How do I connect DYNAmflow to my control system?

Usually via the analogue output (0/4–20 mA, alternatively 0/2–10 V), digitally via RS485 (Modbus RTU). A relay output and a transistor output are available for limit values. We agree the assignment with you in the application check.

What applies in hazardous areas?

DYNAmflow is approved for dust zone 20 inside the pipe and zone 21 outside, and is available in a version for gas zone 2.

Application check

Have your measuring point checked free of charge

You will receive our migration guide and the mass flow questionnaire. Our bulk solids experts will get back to you with an assessment of your measuring point.

  • Assessment of bulk material, conveying type and installation situation
  • Clarification of installation, Ex zone and connection
  • Quotation for the replacement, for several measuring points on request

Prefer to talk directly?

Book a call with our bulk solids experts.

Book a call